Santa María Dams
Santa María Dam is located on the Baluarte River in El Rosario municipality. The reservoir will have useful storage capacity of 723Mm3, according to Conagua, Two Francis type turbines of 15MW will generate 231GWh a year.Supply of instrumentation as part of the monitoring system of the Santa María Dam. The dam consists of a rockfill […]
FAQ#018 – What kind of overvoltage protection is built in the vibrating wire piezometers?
A plasma surge arrestor is wired in parallel with the coil (which is used to pluck the wire). The nominal impulse discharge current 8-20 microsec interval is 10 KA. Impulse spark-over voltage at 1Kv/ microsec: 700 V.
FAQ#016 – Are the vibrating wire piezometers equipped with temperature sensors, or is the temperature sensor an option?
Yes, each vibrating wire piezometer, as every Sisgeo vibrating wire instrument, is equipped with a built-in NTC thermistor YSI 44005 type (3000 Ohm at 25°C). Thermistor is not a option for vibrating wire instruments and therefore there is not additional cost for it.
Vibrating Wire multipoint piezometers
Vibrating Wire multipoint piezometers Reference products codes: PK45MMultipoint vibrating wire piezometers, also called multilevel piezometers, provide measurements of pore-water pressure at different elevations in the same borehole. Isolation of the pore-water pressure at each elevation is achieved by the fully-grouted installation method. APPLICATIONS • Measurement of ground water pressure at different elevations• Monitoring soil consolidation […]